NO.2 MIL COMES ON


BHE010300103W04

2

MIL COMES ON

DESCRIPTION

The MIL is illuminated incorrectly.

POSSIBLE CAUSE

• PCM illuminates for emission-related concern (DTC is stored in PCM)
• Instrument cluster malfunction
Note
• If MIL blinks at steady rate, misfire condition could exist.

Diagnostic procedure

STEP

INSPECTION

RESULTS

ACTION

1
Connect the WDS or equivalent to the DLC-2.
Retrieve any DTCs.
Are there DTCs displayed?
Yes

DTC is displayed:

Go to the applicable DTC inspection.
(See DTC TABLE.)
No

No DTC is displayed:

Go to the next step.
2
Inspect between the following wiring harnesses.
• PCM terminal 4V-instrument cluster terminal 1J
• PCM terminal 4S-instrument cluster terminal 1L
Are they normal?
Yes
Inspect the instrument cluster operation.
No
Repair or replace the wiring harness.
3
Verify test results.
• If normal, return to the diagnostic index to service any additional symptoms.
• If the malfunction remains, inspect the related Service Information and perform the repair or diagnosis.